Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Zibo Decent Machinery Co., Ltd.  

fan blower, Dust Collector, Water Mist Spray cannon, Mining Equipment, Semi Trailer

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Zibo Decent Machiner
  • 电话:00000000
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > Decent HVAC Air Handing Unit
Decent HVAC Air Handing Unit
单价 $900.00 / Piece对比
询价 暂无
浏览 50
发货 Chinashandong
库存 1000Piece
过期 长期有效
更新 2020-04-05 15:15
 
详细信息
Product Name: Decent HVAC Air Handing Unit Model NO.: DCT-1196 Condition: New Power Type: AC Power Source: Electrical Cooling/Heating: Cooling/Heating China Energy Efficiency Standard: Level 3 Certification: CE, CCC, RoHS, UL, SGS Indoor Machine Noise: 36-49dB Usage: Room Capacity: 27000-48000 BTU Type: Inverter Air Conditioner Trademark: DECENT Transport Package: Standard Specification: Standard Origin: China HS Code: 84159090 Product Description Cabinet bodyThe cabinet frame is made of aluminum profiles. The material for panels is PU, PE or glass cotton. polyester foam as a whole. The cabinet has advantages of anti-corrosion, beautiful, durable and small air leakage rate.Air filterAHU Filters is specifically designed for Air Handling Unit, which are widely used for filtering the air and thus, ensure clean air for healthy breathing. Our assortment of AHU Filters is used for proper ventilation &suctions of AHU's installed at hospitals, hotels, malls and other such establishments.The specially designed plate filter can be freely extracted from the left, right, upper and lower sides of the unit, so it is especially suitable for the maintenance and cleaning of compact space.The filter material can be made of cotton concave and convex net or non-woven fabric.Optional Filter Class:G4+F7+H10+H13:FanThe fan is centrifugal type fan with low noise and high efficiency external rotor. The fan is balance corrected precisely to ensure its stable operation, low noise, small vibration and superior performance.The definition of air handling unit from ANSI/AHRI Standard 430-2009 states that it is "A factory-made encased assembly consisting of afan or fans and other necessary equipment to perform one or more of the functions of circulating, cleaning, heating, cooling, humidifying, dehumidifying and mixing of air...."The AHU is used to control the following parameters of the space.TemperatureHumidityAir MovementAir CleanlinessAn Air Handling Unit (AHU) is used to re-condition and circulate air as part of aheating, ventilating and air-conditioning system.The basic function of the AHU is take in outside air, re-condition it and supply it as fresh air to abuilding. All exhaust air is removed, which creates an acceptable indoor air quality. Depending on the required temperature of the re-conditioned air, the fresh air is either heated by arecovery unit or heating coil, or cooled by acooling coil.In buildings, where the hygienic requirements for air quality are lower, some of the air from the rooms can be re-circulated via amixing chamber and this can result in significant energy savings. Amixing chamber has dampers for controlling the ratio between the return, outside and exhaust air.The AHU is alarge metal box containing separate ventilators for supply and exhaust, heating coil, cooling coil, heating/cooling recovery system, air filter racks or chambers, sound attenuators, mixing chamber, and dampers. AHUs connect to ductwork that distributes the conditioned air through the building, and returns it to the AHU.A heat/cooling recovery exchanger is normally fitted to the AHU for energy savings and increasing capacity.An AHU designed for outdoor use, typically on roofs, is also known as arooftop unit (RTU).The following is just for your reference:Air flow4ROW6ROW8ROWTCSCWaterflowWaterresistanceTCSCWaterflowWaterresistanceTCSCWaterflowWaterresistancem³/hkWkWL/SkPakWkWL/SkPakWkWL/SkPa21108.507.770.381.013.4010.190.623.416.4511.520.766.1364019.4315.320.916.026.6518.831.2614.931.1920.851.4624.8518030.2922.771.4316.139.8727.491.8836.345.8630.192.1559.3558029.3123.131.397.340.3528.501.9216.947.3731.622.2527.7799046.0834.702.1818.961.0142.042.8740.963.6963.513.069.21041063.4046.513.0137.873.8252.323.5310.987.0958.204.1818.11282079.6357.843.6859.794.2365.744.4718.3110.1072.835.2630.31080062.4046.852.9816.082.4456.723.9536.294.9962.374.5258.31409085.3062.634.0631.499.5370.544.7710.8117.5878.545.5617.917380108.7378.645.1854.1127.5888.966.0818.4149.3298.667.1830.420670117.5188.605.6313.3156.33107.687.5129.4180.23118.438.6046.117030103.8875.964.9934.8120.3085.205.7610.8142.1194.876.7917.920980131.1294.816.1956.7153.81107.247.3318.5179.44228.698.4829.524930141.99106.926.8213.4188.68129.869.0929.6217.35142.7710.3746.328890169.72125.988.1319.9222.26151.9710.5141.6234.26157.8311.2214.625650158.78115.217.3759.7188.76131.349.0818.9220.20145.4010.5830.630470173.25130.488.3113.4230.47158.6011.1029.6266.12174.6412.6746.336010204.73154.149.8315.0272.10187.2713.0732.3314.43206.3114.9750.041720245.31181.8911.8022.4320.99219.3415.2545.8338.41227.8416.3221.547250284.63208.7613.6831.1366.25249.5317.0059.5391.14261.3518.8629.152950306.38227.4314.7335.6419.38283.4120.1786.1445.44295.9021.4638.347930280.50208.3713.3919.6368.50251.8417.6042.3387.50261.1718.5121.554520326.50240.0515.5927.6425.50289.1120.3358.8450.50301.1721.5329.561100375.50272.9217.9437.8435.50306.5520.8126.1513.50341.1924.5439.059970360.50264.5617.2227.5468.50318.1822.3958.4496.50331.6623.7324.067210410.50299.1519.6137.0527.11357.4324.4072.9565.50375.5527.0331.874450462.50334.5522.1048.6540.50377.5825.8327.0634.50419.4730.3340.881220504.50364.9224.1151.0590.50412.2528.2229.8692.50457.7133.1044.594760589.50426.0728.1756.5688.50480.7432.9135.5805.50532.9138.5152.198500616.50444.4129.4754.6720.50501.7234.4421.7842.50556.1940.2834.5107720682.50489.4032.6268.9800.50556.5638.2727.3932.50613.0644.5843.3116940731.99527.5533.0173.8880.50606.1642.0933.71018.50668.2048.6952.8124060774.96558.9634.5872.2933.50642.7944.6328.91081.50709.3051.7146.3133930821.00596.8533.9673.21018.50698.4548.6935.21174.50768.7456.1656.0143810842.50624.9440.2819.71102.50753.7052.7142.11269.50829.0960.7067.0153680913.50673.2443.6723.61190.50810.6456.9250.21353.22884.4862.1872.8160720920.50689.7844.0118.91220.50837.3758.3640.01402.99919.6465.5359.51725701010.50749.6648.3123.11323.50904.5963.2848.01391.50938.0166.5428.31844201095.50812.7552.3827.61427.50972.2668.2656.81506.501010.6672.0433.31962701180.50865.4456.4432.51530.501039.5173.1966.51621.501083.3577.5438.8Air-handling unit installation instructionsIn units neighboring, especially the side with maintenance door and external water pipe, enough space should be reserved for filter extraction and maintenance.A horizontal base is indispensable. Any slant base will affect normal water drainage of water pond and working fan's dynamic balance.Air is sucked in by unit. The heating hot water temperature must not be higher than 65ºC. The water must be cleaned (soft water). Awater filter is needed if necessary.The condensate pipe of units must be equipped with steam trap. The height of it can be measured through residual pressure +height of 100nn water (following picture is the specific requirement), and asmooth condensate pipe and drainage slope be higher than 0.005 must be assured.Weight of air pipes and water pipes connected to the units must be born by ahanger or support column not the unit itself.The electric motor power supply must have protection when the power lacks phase or is overloaded. Voltage reduction should be started in amotor with power more than 11Kw. Units power supply is 380V, 50Hz.After the installation, before switching on the power, please rotate the leaves of fan with hand to check if they are in good condition. Don't forget to check the voltage to see if it is the right one, without missing phase or is an imbalance triphase. After power on, first of all, switch on the electric power to check if the fan rotates in the right direction, if not, please change the phase sequence. only without exceptions can the unit be put to use. No empty running for the unit.Before the unit starts, air inlet and outlet valve should be half open. After the start, please adjust the opening space of air valve to make sure that the motor runs within rated current.Air filter should be cleaned regularly. During non-use period in winter, measures of freezing-proof are necessary, or empty the coil to prevent it from frost cracking.After two years of operation, acomprehensive maintenance is necessary for the unit, including cleaning dirt on heat exchanger fins and scale in water pipes.A professional technician is needed if the unit breaks down.Ordering GuidePlease be sure of the size, model, cool and heat quantity and left/right form in selecting air handling unit.Electrical controller is not part of the unit. However, the electric protector and air quantity speed regulation (including variable frequency controller and thyristor controller) is addable according to clients' needs. Neither is inlet and outlet air quantity valve part of the unit. Please inform us before ordering if you need it.Our products are not limited to our routine units. According to clients' special needs, unit can be equipped with additional electrical (auxiliary) heater, humidifier (steam humidifier, wet membrane humidifier, high-pressure spray humidifier and electrode humidifier), silencerand so on.Our company follows the principle of constantly improving our products. Please kindly excuse us if we do not inform you in time about changes or improvement of product performance, specifications, and materials, and keep in touch with us to obtain the latest information.about usDecent Machinery Co., Ltd. (DM) is alarge-scale key enterprise in China construction machinery industry and anational high-tech enterprise. DM's main products include four series: Wheel Loader, Excavator and Road Machinery,truck, totally over 100 models. DM is awarded Top 100 in Chinese Machinery Industry, Leading enterprise in China Industrial Sectors, National Good Credit Enterprise and National May 1Labor Award, etc.DM maintains good cooperation relationship with domestic key colleges/universities and research institutes and established open and highly efficient technical cooperation and innovation system. DM established anational technology center and post-doctoral work station, undertakes aplenty of national 863 programs and provincial& above level scientific research projects, has already achieved over 130 national patents.DM has advanced tooling, inspection equipment and well-established management system to ensure product performance and quality. DM keeps aleading position in customer satisfaction and market share in the industry.DM upholds the core value of "Efficiency first, Technology takes the lead", adheres to technology innovation and management innovation, comprehensively introduces and implements excellent performance management and lean production system (LPS); applies precision marketing and brand strategy which all continuously improve overall operational efficiency and enable DM amajor municipal and provincial contributor to tax.